Expansion vessel switch not turning off pump

General Forum

Moderators: PoshinDevon, Soner, Dragon

Post Reply
Chelsea
Kibkommer
Kibkommer
Posts: 96
Joined: Fri 25 Aug 2017 10:28 am

Expansion vessel switch not turning off pump

  • Quote
  •   Message 1 of 17 in Discussion

Post by Chelsea »

I need someone to set switch on expansion vessel. At the moment the pump is not switching off.

gates
Business contributing to forum
Business contributing to forum
Posts: 2266
Joined: Sat 25 Aug 2012 6:42 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 2 of 17 in Discussion

Post by gates »

Where are you based

Chelsea
Kibkommer
Kibkommer
Posts: 96
Joined: Fri 25 Aug 2017 10:28 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 3 of 17 in Discussion

Post by Chelsea »

Hi we are in Kayalar

gates
Business contributing to forum
Business contributing to forum
Posts: 2266
Joined: Sat 25 Aug 2012 6:42 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 4 of 17 in Discussion

Post by gates »

Sorry to far for me

thornaby
Kibkommer
Kibkommer
Posts: 990
Joined: Sat 14 Apr 2012 10:30 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 5 of 17 in Discussion

Post by thornaby »

Consider getting rid of the expansion vessel and existing switch and fitting an electonic switch. This is the modern way to control the pump. Also it may not be the switch. You could have a leak big enough so the pump will never make pressure and satisfy the switch. Also, you can check the rubber bladder inside the vessel, these do fail but are easilly replaceable.

MikeK
Kibkommer
Kibkommer
Posts: 203
Joined: Fri 24 Aug 2012 4:48 pm

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 6 of 17 in Discussion

Post by MikeK »

Thornaby, any details on the electronic switch please.

thornaby
Kibkommer
Kibkommer
Posts: 990
Joined: Sat 14 Apr 2012 10:30 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 7 of 17 in Discussion

Post by thornaby »

Mikek, just visited our local yapi. The cost of the electronic one was 690 tl. It does away with the tank and offers protection that your current system does not. If the electronic one seneses that when it runs it is not making pressure it will shut down and show a red light. Installstion is simple. Remove existing expansion vessel with switch. Screw the new sensor ( pressure controler) in place. There are two cable entries on the side of the controller. One is the feed to the pump. The other is the supply to the controller. That cable / wires may confuse but please give me a shout if i can help

Chelsea
Kibkommer
Kibkommer
Posts: 96
Joined: Fri 25 Aug 2017 10:28 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 8 of 17 in Discussion

Post by Chelsea »

Hi Thornaby, thanks for your advice. We have only last year changed to an expansion vessel. Before that the pump was going on all the time because it sensed the tiniest leak from cistern which was corrected then started again. We got fed up with it & changed to the expansion tank which coped with it well up to now. I think the switch just needs the right adjustment for on/off which with trial & error I’m not able to do.

13roman58
Kibkommer
Kibkommer
Posts: 1980
Joined: Sat 09 Feb 2013 9:29 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 9 of 17 in Discussion

Post by 13roman58 »

Try a non return valve on top of the controller.

susiesusie
Kibkommer
Kibkommer
Posts: 651
Joined: Sat 07 Apr 2012 11:57 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 10 of 17 in Discussion

Post by susiesusie »

690 tl. ( £17) Really!! Are you sure?
I bought one many years ago and they were around £45 then

MikeK
Kibkommer
Kibkommer
Posts: 203
Joined: Fri 24 Aug 2012 4:48 pm

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 11 of 17 in Discussion

Post by MikeK »

Hi Thornaby. is it the type that fits in line above the pump outlet, or is it something new and more hi tech? Many thanks.

thornaby
Kibkommer
Kibkommer
Posts: 990
Joined: Sat 14 Apr 2012 10:30 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 12 of 17 in Discussion

Post by thornaby »

Suzi suzi yes, checked today 680tl, may or may not include tax

thornaby
Kibkommer
Kibkommer
Posts: 990
Joined: Sat 14 Apr 2012 10:30 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 13 of 17 in Discussion

Post by thornaby »

Hi chelsea, good plumbing practises would fit a isolation valve in between the controler and the supply to the house. Assumming this valve is a good shut off, closing it off will tell you if the iissue is a leak downstream of the valve or an iissue with the controller itself.

gates
Business contributing to forum
Business contributing to forum
Posts: 2266
Joined: Sat 25 Aug 2012 6:42 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 14 of 17 in Discussion

Post by gates »

Why don’t you call out a plumber and do it professionally. If there is a leak or a swap come from the tank it needs replaced. Easy really and if not now it will one day

Chelsea
Kibkommer
Kibkommer
Posts: 96
Joined: Fri 25 Aug 2017 10:28 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 15 of 17 in Discussion

Post by Chelsea »

gates wrote:
Tue 04 Jun 2024 2:50 pm
Why don’t you call out a plumber and do it professionally. If there is a leak or a swap come from the tank it needs replaced. Easy really and if not now it will one day
That was my first post asking for someone, unfortunately it’s too far for you.

thornaby
Kibkommer
Kibkommer
Posts: 990
Joined: Sat 14 Apr 2012 10:30 am

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 16 of 17 in Discussion

Post by thornaby »

Mikek yes it fits inline. A non return vale is built into the controller but not a problem leaving the existing one there as well. Installstion not difficult. Definetly a diy job for many. Pipework could be a problem if going from the expansion tank to the electronic controller if you dont have the tool to alter the pipes. An easy fix is to use flexible pipes.

MikeK
Kibkommer
Kibkommer
Posts: 203
Joined: Fri 24 Aug 2012 4:48 pm

Re: Expansion vessel switch not turning off pump

  • Quote
  •   Message 17 of 17 in Discussion

Post by MikeK »

Thanks for the info. Thornaby. :+1:)

Post Reply